PROGRAM MODE SECURITY CODE*
By entering any non-zero value, the prompt   will appear when trying
to access the Program Mode. Access will only be allowed after entering a
matching security code or universal code of . With this lock-out, a user input
would not have to be configured for Program Lock-out. However, this lock-out
is overridden by an inactive user input configured for Program Lock-out.








SP-1 SP-2 SP-3 SP-4 SETPOINT ACCESS*
The setpoint displays can be programmed for ,  or  (see the
following table). Accessible only with the Setpoint plug-in card installed.






5.3 MODULE 3 - DISPLAY ASSIGNMENT AND
PROGRAM LOCK-OUT PARAMETERS ()
PARAMETER MENU
* Factory Setting can be used without affecting basic start-up.
to 
Module 3 is the programming for the Display, Display assignments, Display
lock-out and “Full” and “Quick” Program lock-out.
When in the main Display Mode, the available displays (A,B,C,_) can be
read consecutively by repeatedly pressing the DSP key. An annunciator
indicates the display being shown (_ = No annunciator). A meter display value
can be programmed to one of the displays, to the quick programming mode or
be locked from being visible. It is recommended that the meter display value be
set to  when it is not being used in the application.
“Full” Programming Mode permits all parameters to be viewed and
modified. This Programming Mode can be locked with a security code and/or
user input. When locked and the PAR key is pressed, the meter enters a Quick
Programming Mode. In this mode, the setpoint values can still be read and/or
changed per the selections below. The display Intensity Level ()
parameter also appears whenever Quick Programming Mode is enabled and the
security code greater than zero.
Immediate access.“Full” ProgrammingNot Active

0
No accessQuick ProgrammingActive

0
Immediate access.“Full” ProgrammingNot Active

>0
After Quick Programming with correct code # at  prompt.Quick Programming w/Display IntensityActive

>0
After Quick Programming with correct code # at  prompt.Quick Programming w/Display Intensity————
not 
>0
Immediate access.“Full” Programming————
not 
0
“FULL” PROGRAMMING MODE ACCESS
WHEN PAR KEY IS
PRESSED
USER INPUT
STATE
USER INPUT
CONFIGURED
SECURITY
CODE
PROGRAMMING MODE ACCESS
Throughout this document, Programming Mode (without Quick in front) always refers to “Full” Programming (all meter parameters are accessible).
SELECTION DESCRIPTION









DISPLAY ASSIGNMENT
Not visible in Quick Programming Mode Only
Visible in Quick Programming Mode Only
There are six meter values that can be individually programmed for one of
the main displays (A,B,C or _), or programmed to be viewable in Quick
Programming mode (rEd), or programmed to be locked out from display (LOC)
(see the following table). If two or more values are assigned to the same display
the last value assigned will be the one that is displayed.
LOC
rEd
Not visible in Display Mode or Quick Programming Mode
Visible in Quick Programming Mode only

Assign to Display _ (No annunciator)
dSP-A
Assign to Display A
dSP-b
Assign to Display B
dSP-C
Assign to Display C
Visible and changeable in Quick Programming Mode Only